Fiber Optic Oxygen Sensor Probe Options
There are several probes available as off-the-shelf items, and others available as custom designs:
"-R" Sensor Probe
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Probe Assembly: | 300 µm aluminum-jacketed fiber assembly |
| Dimensions: | 500 µm OD, 1 m length |
| Pressure: | 300 psi |
| Fiber: | BIF200-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | fine spatial resolution applications |
| Price: | $577 |
![]()
18GThe 18G is a 300 µm optical fiber housed in an 18-gauge stainless steel needle probe.
| Probe Assembly: | 300 µm optical fiber, 18-gauge tip |
| Dimensions: | 1.27 mm diameter, 90 mm length tip |
| Pressure: | 300 psi |
| Fiber: | BIF200-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | penetration of vial septa and rigid packaging |
| Price: | $692 |
![]()
21G
The 21G is a 300 µm optical fiber housed in a 21-gauge stainless steel needle probe.
| Probe Assembly: | 300 µm optical fiber, 21-gauge tip |
| Dimensions: | 813 µm diameter, 90 mm length tip |
| Pressure: | 300 psi |
| Fiber: | BIF200-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | penetration of soft packaging |
| Price: | $692 |
![]()
OR125
The OR125 is a 1/8" OD optical fiber probe used
as a direct replacement for 1/8" OD O2 electrodes.
|
Probe Assembly: |
1000 µm optical fiber, stainless steel ferrule |
|
Dimensions: |
3.175 mm OD, 63.5 mm length |
|
Pressure: |
300 psi |
|
Fiber: |
BIF600-VIS-NIR |
|
Termination: |
SMA 905 |
|
Typical Usage: |
direct replacement for 1/8" OD O2 electrodes |
|
Price: |
$692 |
![]()
OR125G
The OR125 is a 1/8" OD optical fiber probe used
as a direct replacement for 1/8" OD O2 electrodes.
| Probe Assembly: | 1000 µm optical fiber, stainless steel ferrule |
| Dimensions: | 3.175 mm OD, 63.5 mm length |
| Pressure: | 300 psi |
| Fiber: | BIF600-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | direct replacement for O-ring grooved electrodes |
| Price: | $692 |
![]()
OR125GT
The OR125 is a 1/8" OD optical fiber probe used
as a direct replacement for 1/8" OD O2 electrodes.
| Probe Assembly: | 1000 µm optical fiber, titanium ferrule |
| Dimensions: | 3.175 mm OD, 63.5 mm length |
| Pressure: | 300 psi |
| Fiber: | BIF600-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | direct replacement for O-ring grooved electrodes |
| Price: | $751 |
![]()
T1000The T1000 is a
6.35 mm OD optical fiber probe used in process environments and
high-pressure applications.
| Probe Assembly: | 1000 µm optical fiber, stainless steel ferrule |
| Dimensions: | 6.35 mm OD, 177.8 mm length |
| Pressure: | 3000 psi |
| Fiber: | BIF600-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | process environments, high-pressure applications |
| Price: | $1154 |
![]()
T1000-RTDThe T1000-RTD is a 6.35-mm OD optical fiber probe with an embedded RTD used in process environments. The T1000 RTD can only be used in conjunction with the USB-LS-450.
| Probe Assembly: | 1000 µm optical fiber, 1/8" OD stainless steel |
| Dimensions: | 6.355 mm OD, 177.8 mm length |
| Pressure: | 300 psi |
| Fiber: | BIF600-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | process environments, includes embedded RTD |
| Price: | $1732 |
![]()
PI600
The PI600 is a silicone-jacketed, polyimide-coated optical fiber probe
used in environments where a non-metallic probe is required.
| Probe Assembly: | 600 µm optical fiber with silicone jacketing |
| Dimensions: | 710 µm OD, 2 m length |
| Pressure: | 300 psi |
| Fiber: | BIF400-VIS-NIR |
| Termination: | SMA 905 |
| Typical Usage: | environments where non-metallic probe is indicated |
| Price: | $577 |
![]()
Optional coatings of silicone (both standard and medical-grade) can be applied to Probes to exclude ambient light, improve chemical resistance and eliminate refractive index effects. We recommend an overcoat if your application involves liquids, as well as those that involve changing from gases to liquids, as scattering effects could result in the sensor losing calibration. There is no charge for these overcoats.
| Item | Description | Response in Gases | Response in Liquids |
| -AF | RTV silicone adhesive overcoat (increases probe response time) | 10-30 seconds | 15-45 seconds |
| -AF-MG | High-strength RTV silicone adhesive overcoat is a medical implant-grade silicone | 15-45 seconds | 45-60 seconds (depending on sample viscosity) |
PRODUCTS |
TECHNICAL |
APPLICATIONS |
CORPORATE |
DISTRIBUTORS
| PRIVACY POLICY
CONTACT US |
CATALOG |
PRICE LIST |
ORDER INFO

.
©2007 Ocean Optics, Inc. All rights reserved.
Terms of
Use and Privacy Statement
+1
727.733.2447 • +1 Fax 727.733.3962 •
![]()
Contact an
Ocean Optics
Applications Scientist