Fiber Optic Oxygen Sensor Systems
Fiber Optic Oxygen Sensors are
phase fluorometer-coupled chemical sensors for full spectral analysis of
dissolved and gaseous oxygen pressure. A fluorescence
method is used to measure the partial pressure of dissolved or gaseous oxygen.
A Fiber Optic Oxygen Sensor system will change the way
you work. Because the probe consumes no oxygen, it can be used in continuous
contact with viscous samples so that continuous stirring is no longer required. Now that
there is an alternative to the oxygen electrode, changing membranes and
filling solutions can be avoided. (For a complete list of why our fiber
optic sensors are superior to electrodes,
click here.)
Oxygen Sensor System -- Sample
Setup
Optical fiber carries excitation
light produced by the blue LED to the thin-film coating at the probe tip. Fluorescence
generated at the tip is collected by the probe and carried by the optical fiber to the
multifrequency phase fluorometer. When oxygen in the gas or liquid sample diffuses into the
thin-film coating, it quenches the fluorescence. The degree of quenching correlates to the
level of oxygen pressure.

Oxygen Sensor System -- Sample Order
| Item |
Description |
Price
|
|
MFPF100-1 |
A 1-channel frequency-domain
luminescence monitor. Comes with one thermistor and
can connect to a PC via an RS-232 or USB connection. Data is saved in
an Excel format. |
$5000 |
|
MFPF100-2 |
A 2-channel frequency-domain
luminescence monitor. Comes with two thermistors and
can connect to a PC via an RS-232 or USB connection. Data is saved in
an Excel format. |
$7500 |
|
QBIF-600-VIS-NIR |
600 µm bifurcated optical fiber assembly;
optimized for VIS/NIR.
|
Call for Price |
| 21-02 |
SMA splice bushing for connecting
fiber optic sensor probes to bifurcated fiber assemblies.
|
$14 |
| FOXY-R |
1000
µm fiber in a 1/16" OD stainless steel
ferrule with FOXY Sensor Formulation applied to the tip of the
probe |
$577 |
| FOXY-AF
(optional) |
Silicone
overcoat applied to probe to exclude ambient light, improve
chemical resistance and eliminate refractive index effects |
No charge |
| FOXY-CAL
(optional) |
Calibration
option for sensor systems configured with temperature-compensation
accessories; users must specify the temperature and the
concentration range for their applications. |
$230 |
| OOISensors |
32-bit,
Windows-based operating software acquires data, converts the data
into oxygen concentration, and saves the data in spectral files
and logs. |
$199 |