The USB2000-FLG is a high-sensitivity spectrofluorometer that is preconfigured for fluorescence applications from 380-1050 nm. We utilize a proprietary thin film technology and a time-gated spectrometer to provide a spectrofluorometer that is 20 percent more sensitive than the standard USB2000 Spectrometer. The USB2000-FLG is available for $3299. |
AgPlus Mirrors increase system sensitivity by 20% over standard USB2000
Gated mode eliminates scattered excitation light to enhance phosphorescence measurements
Full 380-1050 nm range analysis
We replaced our standard mirrors with our proprietary AgPlus Ag-coated mirrors to increase reflectance, which in turn increases the sensitivity of the spectrometer by 10-35% percent. Not only do these mirrors create a more sensitive spectrometer, they also absorb nearly all UV light, virtually eliminating the excitation source's spectra from interfering with the sample spectra. Pairs of AgPlus mirrors (item SAG+UPG) are available for $250.
The USB2000-FLG is preloaded with variable-delay gating microcode, which allows you to select a delay (from 5-500 microseconds) between the light turning on and the start of the spectrometer's integration time, or the amount of time the detector "sees" the sample. In this mode, the spectrometer only detects the sample light when the source is off. However, in order to use the gated phosphorescence mode, your fluorophore must have a long fluorescence lifetime. Those working with lanthanides and phosphorescent materials will find the gated phosphorescence mode particularly useful.
The USB2000-FLG's detector window is fitted with an L2 Detector Collection Lens. This cylindrical lens increases the spectrometer's light-collection efficiency and reduces stray light. The L2 is especially useful with a large-diameter fiber for low light-level applications.
The USB2000-FLG can be used with our LVF-series Linear Variable Filters to construct systems with excellent separation of excitation and fluorescence energy. Use our LVF-L Linear Variable Low-pass Filter to fine tune your excitation source for maximum signal with minimum overlap; and/or use our LVF-H Linear Variable High-pass Filter on the detection side. Inline holders and cuvette fixtures make deployment of these filters easy.
The USB2000-FLG can detect fluorophores in liquids and powders, and from surfaces. We use the USB2000-FLG in our EDS2000 System to detect anthrax. The USB2000-FLG is field-portable -- use it to detect fluorescence in coral, fruit and other flora and fauna.

This graph shows the fluorescence of
nanomolar (nM) concentrations of fluorescein. We made the
measurements with a USB2000-FLG, an LS-450 Blue LED Light Source, a
CUV-ALL and an LVF-L Low-pass Filter to limit the blue LED to <
475 nm. We set the integration time to 100 msec. Longer integration times allow the system to detect
fluoroscein in the picomolar range.
|
Spectrometer: |
USB2000-FLG; Master spectrometer channel only |
|
Grating: |
Grating #3 -- 600 lines per millimeter, blazed at 500 nm |
|
Detector: |
2048-element linear silicon CCD array; L2 Collection Lens |
|
Wavelength range: |
380-1050 nm |
|
Entrance aperture: |
200 µm wide slit |
|
AgPlus Mirrors: |
Provide reflectivity >95% over the visible and NIR wavelength range and over a wide range of angles of incidence |
|
Integration time: |
5 milliseconds in gated mode, 5 msec-20 seconds in normal mode |
|
Data transfer rate: |
|
|
Optical resolution: |
~10.0 nm FWHM |
|
Stray light: |
~0.05% at 600 nm, <0.10% at 435 nm |
|
Power consumption: |
90 mA @ 5 VDC |
|
Dimensions: |
89.1 mm x 63.3 mm x 34.4 mm |
|
Weight: |
190 g |
|
Computer interface: |
Universal Serial Bus (RS-232 available on side connector) |
|
Computer requirements*: |
|
|
Operating software: |
SpectraSuite (for an additional Call for Price) |
|
Fiber optic connector: |
SMA 905 to single-strand optical fiber |
* Download free software to analyze your computer's USB readiness by clicking here.
PRODUCTS |
TECHNICAL |
APPLICATIONS |
CORPORATE |
DISTRIBUTORS
| PRIVACY POLICY
CONTACT US |
CATALOG |
PRICE LIST |
ORDER INFO

.
©2007 Ocean Optics, Inc. All rights reserved.
Terms of
Use and Privacy Statement
+1
727.733.2447 • +1 Fax 727.733.3962 •
![]()
Contact an Ocean Optics Applications Scientist
Convenient Wavelength Calibration! Click here for Details
USB4000-FL Fluorescence Spectrometer
LVF-series Linear Variable Filters
CVFL-Q-10 Quartz Cuvettes for Fluorescence
FluoroVette Fluorescence Cells