S1024DW Deep Well Spectrometer
|
 |
The S1024DW Deep Well Detector Spectrometer
features a 1024-element photodiode array detector for applications requiring
high signal-to-noise (S:N) measurements.
-
Reliably
observe an change of less than 0.00001 absorbance
units
-
Ideal for high light
level applications involving solution absorbance, transmission and
dissolution testing
-
Can
be multiplexed with up to 8 spectrometer channels
The S1024DW is available for only $3002.
Additional channels are
just Call for Price.
|
The S1024DW Spectrometer has a compact
optical bench coupled to a 1024-element photodiode array detector. The
S1024DW accepts light energy transmitted through single-strand optical
fiber and disperses it via a fixed grating across the photodiode array,
which is responsive from 200-1100 nm. An SMA 905 connector allows for easy
coupling to an extensive line of fiber optic light sources, probes,
chemical sensors, and other spectrophotometric accessories.
The S1024DW can be multiplexed with up to 8
spectrometer channels, all of which run from a single A/D converter, the
ADC1000-USB.
User's Tip: The S1024DW
is our standard deep well detector spectrometer. Also available is the
S1024DWX, with a detector distinguished by its large pixel size and
large well depth. The S1024DWX is available on a special-order
basis starting at Call for Price.
S1024DW Spectrometers Specifications
Signal-to-noise for all
detectors is limited by the number of sampled photons. The S1024DW has a large well depth
detector with high S:N that makes it especially useful for high light
level absorbance applications.
|
Features
|
S1024DW
Deep Well Detector Spectrometers
|
S1024DWX
Deep Well Detector Spectrometers
|
|
Detector:
|
Hamamatsu
S3903 linear photodiode array
|
Hamamatsu
S3904 linear photodiode array
|
|
# of
pixels:
|
1024
|
1024
|
|
Pixel
size:
|
25 x 500
µm
|
25 x
2500 µm
|
|
Effective
range:
|
200-1100
nm
|
200-1100
nm
|
|
Signal-to-noise
(at full signal):
|
2500:1
|
2500:1
|
|
Well
depth:
|
31
million electrons
|
156
million electrons
|
|
A/D
resolution
(minimum required):
|
12-bit
|
12-bit
|
|
Integration
time:
|
31
milliseconds to 65 seconds (with 500 kHz A/D card)
|
31
milliseconds to 65 seconds (with 500 kHz A/D card)
|
|
Dark
noise
(RMS counts):
|
1-2
|
1-2
|
|
Corrected
linearity:
|
>99.8%
|
>99.8%
|
|
Gratings: |
14 gratings; UV, VIS
and Shortwave NIR options |
14 gratings; UV, VIS
and Shortwave NIR options |
|
Slits: |
5, 10, 25, 50, 100, 200
µm widths (1000 µm slit height); no slit option also available |
5, 10, 25, 50, 100, 200
µm widths (1000 µm slit height); no slit option also available |
|
Order-sorting: |
Single-piece, multi-bandpass
detector coating (OFLV-DW-350) for applications from ~200-850 nm
(available only with Grating #1 and Grating #2) or Schott glass
longpass filters (installed or loose) |
Single-piece, multi-bandpass
detector coating (OFLV-DW-350) for applications from ~200-850 nm
(available only with Grating #1 and Grating #2) or Schott glass
longpass filters (installed or loose) |
|
Optical resolution: |
~0.3-10.0 nm FWHM |
~0.3-10.0 nm FWHM |
|
Stray light: |
<0.05% at 600 nm
<0.10% at 435 nm
<0.10% at 250 nm |
<0.05% at 600 nm
<0.10% at 435 nm
<0.10% at 250 nm |
|
Fiber optic connector: |
SMA 905 to
single-strand optical fiber (0.22 NA) |
SMA 905 to
single-strand optical fiber (0.22 NA) |
PRODUCTS |
TECHNICAL |
APPLICATIONS |
CORPORATE |
DISTRIBUTORS
| PRIVACY POLICY
CONTACT US |
CATALOG |
PRICE LIST |
ORDER INFO

.
©2007 Ocean Optics, Inc. All rights reserved.
Terms of
Use and Privacy Statement
+1
727.733.2447 • +1 Fax 727.733.3962 •

|
|
Contact an Ocean Optics Applications Scientist
Convenient Wavelength Calibration!
Click here for Details
|