HR6 Spectrometers
High Sensitivity and Excellent Resolution
HR6 spectrometers offer high sensitivity, high resolution and excellent SNR performance for applications including absorbance of proteins and emission of broadband sources. For measurements requiring sub-nanometer resolution of spectral features, HR6 is a great choice.
Documents
Manual
Drawing
Step File
Comms Protocol
HR6 Series
Disclaimer: Wavelength range and optical resolution specifications are typical values. Actual performance may vary depending on configuration, selected components, and operating conditions.
Specifications
Part Number
Wavelength Range
Optical resolution (FWHM in nm)
Grating Groove Density (lines/mm)
Grating Blaze Wavelength
Available at Edmund Optics25 μm slit only
5 μm slit 10 μm slit 25 μm slit 50 μm slit 100 μm slit 200 μm slit
UV-Vis options: HR-6UVV300-XX 200 – 650 nm 0.35 0.46 0.58 0.97 1.84 3.54 600 300 nm Buy Now
Vis options: HR-6VIS500-XX 400 – 840 nm 0.35 0.46 0.58 0.97 1.84 3.54 600 500 nm Buy Now
UV options: HR-6UV220-XX 180 – 325 nm 0.12 0.16 0.20 0.34 0.64 1.23 1800 Holographic —
HR-6UV250-XX 180 – 400 nm 0.17 0.22 0.28 0.46 0.88 1.69 1200 Holographic —
HR6-UV240-XX 185 – 280 nm 0.08 0.10 0.13 0.21 0.40 0.77 2400 Holographic —
UV-Vis options: HR-6UVV250-XX 180 – 870 nm 0.53 0.70 0.88 1.47 2.80 5.39 400 250 nm —
HR-6UVV330-XX 250 – 790 nm 0.44 0.58 0.73 1.22 2.32 4.47 500 330 nm —
Vis options: HR-6VIS400-XX 350 – 800 nm 0.35 0.46 0.58 0.97 1.84 3.54 600 400 nm —
HR-6VIS450-XX 450 – 500 nm 0.08 0.10 0.13 0.21 0.40 0.77 2400 Holographic —
HR-6VIS550-XX 450 – 650 nm 0.17 0.22 0.28 0.46 0.88 1.69 1200 Holographic —
HR-6VIS600-XX 530 – 630 nm 0.12 0.16 0.20 0.34 0.64 1.23 1800 Holographic —
Vis-NIR options: HR-6VN400-XX 340 – 1025 nm 0.52 0.70 0.88 1.47 2.80 5.39 400 400 nm —
HR-6VN750-XX 520 – 950 nm 0.35 0.46 0.58 0.97 1.84 3.54 600 750 nm —
NIR options: HR-6N500-XX 750 – 1000 nm 0.27 0.36 0.45 0.76 1.44 2.77 900 500 nm —
HR-6N750-XX 750 – 900 nm 0.17 0.22 0.28 0.46 0.88 1.69 1200 750 nm —
HR-6N1000-XX 750 – 1100 nm 0.35 0.46 0.58 0.97 1.84 3.54 600 1000 nm —
Ethernet options: HR-6UV220EN-XX 180 – 400 nm — — 0.20 — — — 1800 Holographic —
HR-6UVV250-EN-XX 180 – 870 nm — 0.70 — — — — 400 250 nm —
HR-6UVV250EN-XX 180 – 870 nm 0.53 — — — — — 400 250 nm —
HR-6UVV300EN-XX 200 – 650 nm — — 0.58 — — — 600 300 nm —
HR-6UVV330EN-XX 250 – 790 nm — 0.58 — — — — 500 330 nm —
HR-6XR200EN-XX 200 – 1000 nm — 0.94 — 1.97 — — 300 200 nm —
HR-6XR500EN-XX 190 – 1100 nm 0.71 — — — — — 300 500 nm —
Extended-range options: HR-6XR200-XX 220 – 1000 nm 0.71 0.94 1.18 1.97 3.76 7.24 300 200 nm —
HR-6XR300-XX 200 – 1100 nm 0.71 0.94 1.18 1.98 3.76 7.24 300 Composite —
HR-6XR500-XX 190 – 1100 nm 0.71 0.94 1.18 1.97 3.76 7.24 300 500 nm —
Slit Options
5, 10, 25, 50, 100, 200 µm
Integration time
7.2 ms – 5 s
SNR (single scan @ 10 ms)
400:1
SNR (max. per second w/High Speed Averaging Mode)
3,500:1
Connectors
SMA, TFM-108-02-L-DH Samtec, USB Type-C
Physical dimensions
148.8 x 106.4 x 48.2 mm
Weight
0.9306 kg
Temperature (operation)
0 °C – 55 °C
Temperature (storage)
-30 °C – 70 °C
High Resolution Spectrometers Product Support
Access user manuals, technical tips, and application notes for your spectrometer.
Assembly Guides
Product Sheets
Operations Manuals
Helpful Tools