Spectroscopy Kits

Our Spectroscopy Kits provide users with versatile tools for understanding absorbance, reflectance, and other techniques. The Spectroscopy Kits are ideal for educational institutions, research labs and individuals seeking a complete solution for hands-on experiments in fields including physics, chemistry, biology, and environmental science.
Each kit provides the essential components — spectrometer, light source, optical fiber and sampling accessories — required for performing a wide range of spectroscopic experiments, making it a valuable tool for learning and research. Each kit also comes with FREE software for data acquisition, analysis, and visualization.
Find the Right Kit
In assembling these kits, we’ve drawn on our vast experience helping customers configure setups and have considered each user’s expertise level, measurement objectives, and performance expectations.
We have optimized kits for a specific application type such as color measurement or biofluid analysis (Focused Kits) or for a certain sample state (General Kits).
Answer These 3 Key Questions
- What type of sample or application are you measuring?
– Solid, liquid, or plasma samples; color analysis, or biofluid analysis. - How large is your sample?
– Small (microliters to milliliters) or bulk (larger volume or surfaces). - What performance level do you need?
– Essential, Enhanced, or Superior.
General Kits
Solids – Small Sample
If your sample is small — 50 mm x 50 mm or less — an integrating sphere offers great versatility and high repeatability.

ESSENTIAL
SL-KIT-ST-SAM

ENHANCED
SL-KIT-SR-SAM

SUPERIOR
SL-KIT-HR-SAM
| Part Number | Sample | Sample Size | Wavelength Range | Spectrometer | Light Source | Fiber/Probe | Accessories |
| SL-KIT-ST-SAM | Solid | Small | 645-1085 nm | ST-NIR-10 | ISP-REFL | QP600-025-VIS-NIR | WS-1 |
| SL-KIT-SR-SAM | Solid | Small | 400-1050 nm (190-1050 nm potential) | SR-6XR250-10 | ISP-REFL | QP600-025-VIS-NIR | WS-1 |
| SL-KIT-HR-SAM | Solid | Small | 400-1100 nm (190-1100 nm potential) | HR-6XR500-10 | ISP-REFL | QP600-025-VIS-NIR | WS-1 |
Solids – Bulk Sample
If your sample is large (bulk) and requires a larger sample area to be scanned, we recommend a reflection probe.

ESSENTIAL
SL-KIT-ST-BLK

ENHANCED
SL-KIT-SR-BLK

SUPERIOR
SL-KIT-HR-BLK
| Part Number | Sample | Sample Size | Wavelength Range | Spectrometer | Light Source | Fiber/Probe | Accessories |
| SL-KIT-ST-BLK | Solid | Bulk | 645-1085 nm | ST-NIR-10 | ECOVIS | QR400-7-VIS-NIR | WS-1 |
| SL-KIT-SR-BLK | Solid | Bulk | 400-1050 nm (190-1050 nm potential) | SR-6XR250-10 | HL-2000-HP | QR400-7-UV-VIS | WS-1 |
| SL-KIT-HR-BLK | Solid | Bulk | 190-1100 nm | HR-6XR500-200 | DH-2000-S-DUV-TTL | QR400-7-UV-VIS | WS-1 |
Liquids – Small Sample
For small-volume samples (1-3.5 mL), we recommend standard cuvettes, which provide repeatable sample characterization and variable pathlengths.

ESSENTIAL
LQ-KIT-ST-SAM

ENHANCED
LQ-KIT-SR-SAM

SUPERIOR
LQ-KIT-HR-SAM
| Part Number | Sample | Sample Size | Wavelength Range | Spectrometer | Light Source | Fiber/Probe | Accessories |
| LQ-KIT-ST-SAM | Liquid | Small | 350-810 nm | ST-VIS-10 | ECOVIS | QP230-025-XSR | CVD-UV1S |
| LQ-KIT-SR-SAM | Liquid | Small | 220-800 nm (220-1050 nm potential) | SR-2XR250-10 | PX-2 | 2 pcs of QP600-025-XSR | SQ1-ALL CVD-UV1S |
| LQ-KIT-HR-SAM | Liquid | Small | 190-1100 nm | HR-2XR500-10 | DH-2000-S-DUV-TTL | 2 pcs of QP600-025-XSR | SQ1-ALL CVD-UV1S |
Liquids – Bulk Sample
For larger vessels and high-volume samples, your best bet is a transmission dip probe, which allows you to continuously measure fluids with variable pathlengths and can be integrated into process streams for in situ measurements.

ESSENTIAL
LQ-KIT-ST-BLK

ENHANCED
LQ-KIT-SR-BLK

SUPERIOR
LQ-KIT-HR-BLK
| Part Number | Sample | Sample Size | Wavelength Range | Spectrometer | Light Source | Fiber/Probe | Accessories |
| LQ-KIT-ST-BLK | Liquid | Bulk | 350-810 nm | ST-VIS-10 | ECOVIS | T300-RT-UV-VIS | RT-10MM |
| LQ-KIT-SR-BLK | Liquid | Bulk | 220-800 nm (220-1050 nm potential) | SR-2XR250-10 | PX-2 | T300-RT-UV-VIS | RT-10MM |
| LQ-KIT-HR-BLK | Liquid | Bulk | 190-1100 nm | HR-2XR500-10 | DH-2000-S-DUV-TTL | T300-RT-UV-VIS | RT-10MM |
Focused Kits
Plasma/Emission & Fluorescence
When choosing a kit, always consider first what you’re trying to accomplish. Whether it’s plasma monitoring or fluorescence detection, each measurement challenge presents a new set of expectations — and a path to the best kit for your needs.

ESSENTIAL
PL-KIT-ST

ENHANCED
PL-KIT-SR2

ENHANCED
PL-KIT-SR

SUPERIOR
PL-KIT-HR

FLUORESCENCE
FL-KIT-SAM
Add-On to any of the Plasma/Emission Kits

FLUORESCENCE
FL-KIT-BLK
Add-On to any of the Plasma/Emission Kits
| Part Number | Sample | Sample Size | Wavelength Range | Spectrometer | Light Source | Fiber/Probe | Accessories |
| PL-KIT-ST | Plasma/Emission | NA | 185-650 nm | ST-UV-25 | — | QP600-1-XSR | CC-3-UV-S |
| PL-KIT-SR2 | Plasma/Emission | NA | 220-1050 nm | SR-2XR250-25 | — | QP600-1-XSR | CC-3-UV-S |
| PL-KIT-SR | Plasma/Emission | NA | 220-1050 nm | SR-4XR250-25 | — | QP600-1-XSR | CC-3-UV-S |
| PL-KIT-HR | Plasma/Emission | NA | 220-1100 nm | HR-4XR500-25 | — | QP600-1-XSR | CC-3-UV-S |
| FL-KIT-SAM | Fluorescence | Small | 180-900 nm* | Add-On to any of the Plasma/Emission Kits | LED-GP-KIT | QP600-025-XSR | SQ1-ALL CVFL-Q-10 |
| FL-KIT-BLK | Fluorescence | Bulk | 300-1100 nm* | Add-On to any of the Plasma/Emission Kits | LED-GP-KIT | QR400-7-UV-VIS | — |
Color Measurements
Use the CLR-KIT-ST to measure reflected color of solid surfaces. For broader spectral coverage and greater thermal stability, the CLR-KIT-SR kit with SR6 spectrometer anchors this integrating sphere-based system. And for reliable color matching of samples such as LEDs or finished goods, use the CLR-KIT-HR with high-resolution HR6 spectrometer.
Pro Tip: It’s more of a box than a sphere, but either way your integrating sphere is the go-to tool for repeatable color measurements.

ESSENTIAL
CLR-KIT-ST

ENHANCED
CLR-KIT-SR2

ENHANCED
CLR-KIT-SR

SUPERIOR
CLR-KIT-HR
| Part Number | Sample | Wavelength Range | Spectrometer | Light Source | Fiber/Probe | Accessories |
| CLR-KIT-ST | Color | 350-810 nm | ST-VIS-10 | ISP-REFL | QP600-025-UV | WS-1 |
| CLR-KIT-SR2 | Color | 350-910 nm (220-910 nm potential) | SR-2UVV400-10 | ISP-REFL | QP600-025-UV | WS-1 |
| CLR-KIT-SR | Color | 350-910 nm (200-910 nm potential) | SR-6UVV400-10 | ISP-REFL | QP600-025-UV | WS-1 |
| CLR-KIT-HR | Color | 350-1025 nm | HR-6VN400-10 | ISP-REFL | QP600-025-VIS-NIR | WS-1 |
Biofluid Analysis
The BIO-KIT-ST captures real-time protein concentration measurements using a dip-probe. To capture broader spectrum with great UV response, use the BIO-KIT-SR. And when dealing with complex biofluid mixtures, use the BIO-KIT-HR with a high-resolution spectrometer to characterize and isolate signals.
Pro Tip: Is your sample >10mL? Our transmission dip probe is ideal for integration into bioreactor head ports.

ESSENTIAL
BIO-KIT-ST

ENHANCED
BIO-KIT-SR

SUPERIOR
BIO-KIT-HR
| Part Number | Sample | Wavelength Range | Spectrometer | Light Source | Fiber/Probe | Accessories |
| BIO-KIT-ST | Biofluid | 185-650 nm | ST-UV-10 | DH-2000-S-DUV-TTL | T300-RT-UV-VIS | RT-10MM |
| BIO-KIT-SR | Biofluid | 220-910 nm | SR-2UVV300-10 | DH-2000-S-DUV-TTL | T300-RT-UV-VIS | RT-10MM |
| BIO-KIT-HR | Biofluid | 220-880 nm | HR-2UVV250-10 | DH-2000-S-DUV-TTL | T300-RT-UV-VIS | RT-10MM |