HR2 Spectrometers

High Speed and High Resolution 

HR2 spectrometers provide reliable performance with rapid acquisition speed and excellent thermal stability for applications ranging from plasma monitoring to pharmaceuticals analysis. Its rugged design makes HR2 ideal for integrating into OEM and process setups.

Documents

Manual

Drawing

Step File

Product Sheet

HR2, HR4, HR6

Comms Protocol

HR2 Series

Disclaimer: Wavelength range and optical resolution specifications are typical values. Actual performance may vary depending on configuration, selected components, and operating conditions.

Group Part Number Wavelength Range Optical resolution (FWHM in nm) Grating Groove Density (lines/mm) Grating Blaze Wavelength Available at Edmund Optics25 μm slit only
5 μm slit10 μm slit25 μm slit50 μm slit100 μm slit200 μm slit
UV-Vis options:HR-2UVV300-XX200 – 650 nm0.350.460.580.971.843.52600300 nmBuy Now
Vis options:HR-2VIS500-XX400 – 850 nm0.41600500 nmBuy Now
NIR options:HR-2N750-XX750 – 900 nm0.160.200.240.4620.881.681200750 nmBuy Now
UV options:HR-2UV220-XX250 – 400 nm0.120.171800Holographic
HR-2UV250-XX190 – 413 nm0.170.220.280.460.881.681200Holographic
UV-Vis options:HR-2UVV250-XX190 – 880 nm0.530.700.841.472.805.36400250 nm
HR-2UVV330-XX250 – 700 nm0.440.430.511.222.324.44500330 nm
Vis options:HR-2VIS400-XX350 – 800 nm0.350.430.510.971.843.52600400 nm
HR-2VIS450-XX450 – 500 nm0.080.110.140.210.400.772400Holographic
HR-2VIS550-XX450 – 650 nm0.170.190.230.460.881.681200Holographic
HR-2VIS600-XX530 – 645 nm0.120.160.200.340.641.221800Holographic
Vis-NIR options: HR-2VN400-XX340 – 1025 nm0.530.700.841.472.805.46400400 nm
HR-2VN750-XX530 – 967 nm0.350.420.500.971.843.52600750 nm
NIR options:HR-2N500-XX735 – 1000 nm0.270.250.300.761.442.75900500 nm
HR-2N1000-XX750 – 1100 nm0.350.380.460.971.843.526001000 nm
Ethernet options:HR-2UV220-EN-XX250 – 400 nm0.121800Holographic
HR-2UV250EN-XX190 – 413 nm0.171200Holographic
HR-2UVV250EN-XX190 – 880 nm0.84400250 nm
HR-2VIS400-EN-XX350 – 800 nm0.35600400 nm
HR-2VIS500EN-XX400 – 850 nm600500 nm
Extended-range options:HR-2XR200-XX220 – 1000 nm0.710.630.781.973.767.19300200 nm
HR-2XR300-XX220 – 1100 nm0.710.941.181.973.767.19300Composite
HR-2XR500-XX190 – 1100 nm0.710.841.131.973.767.19300500 nm
HR-2XR500EN-XX190 – 1100 nm0.84300500 nm
Slit Options 5, 10, 25, 50, 100, 200 µm
Integration time 1 μs – 2 s
SNR (single scan @ 10 ms) 380:1
SNR (max. per second w/High Speed Averaging Mode) 25,800:1
Connectors SMA, TFM-108-02-L-DH Samtec, USB Type-C
Physical dimensions 148.8 x 106.4 x 48.2 mm
Weight 0.9306 kg
Temperature (operation) 0 °C – 55 °C
Temperature (storage) -30 °C – 70 °C