HR6 Spectrometers

High Sensitivity and Excellent Resolution

HR6 spectrometers offer high sensitivity, high resolution and excellent SNR performance for applications including absorbance of proteins and emission of broadband sources. For measurements requiring sub-nanometer resolution of spectral features, HR6 is a great choice.

Documents

Manual

Drawing

Step File

Product Sheet

HR2, HR4, HR6

Comms Protocol

HR6 Series

Disclaimer: Wavelength range and optical resolution specifications are typical values. Actual performance may vary depending on configuration, selected components, and operating conditions.

Specifications Part Number Wavelength Range Optical resolution (FWHM in nm) Grating Groove Density (lines/mm) Grating Blaze Wavelength Available at Edmund Optics25 μm slit only
5 μm slit10 μm slit25 μm slit50 μm slit100 μm slit200 μm slit
UV-Vis options:HR-6UVV300-XX200 - 650 nm0.350.460.580.971.843.54600300 nmBuy Now
Vis options:HR-6VIS500-XX400 - 840 nm0.350.460.580.971.843.54600500 nmBuy Now
UV options:HR-6UV220-XX180 - 325 nm0.120.160.200.340.641.231800Holographic—
HR-6UV250-XX180 - 400 nm0.170.220.280.460.881.691200Holographic—
HR6-UV240-XX185 - 280 nm0.080.100.130.210.400.772400Holographic—
UV-Vis options:HR-6UVV250-XX180 - 870 nm0.530.700.881.472.805.39400250 nm—
HR-6UVV330-XX250 - 790 nm0.440.580.731.222.324.47500330 nm—
Vis options:HR-6VIS400-XX350 - 800 nm0.350.460.580.971.843.54600400 nm—
HR-6VIS450-XX450 - 500 nm0.080.100.130.210.400.772400Holographic—
HR-6VIS550-XX450 - 650 nm0.170.220.280.460.881.691200Holographic—
HR-6VIS600-XX530 - 630 nm0.120.160.200.340.641.231800Holographic—
Vis-NIR options:HR-6VN400-XX340 - 1025 nm0.520.700.881.472.805.39400400 nm—
HR-6VN750-XX520 - 950 nm0.350.460.580.971.843.54600750 nm—
NIR options:HR-6N500-XX750 - 1000 nm0.270.360.450.761.442.77900500 nm—
HR-6N750-XX750 - 900 nm0.170.220.280.460.881.691200750 nm—
HR-6N1000-XX750 - 1100 nm0.350.460.580.971.843.546001000 nm—
Ethernet options: HR-6UV220EN-XX180 - 400 nmN/AN/A0.20N/AN/AN/A1800Holographic—
HR-6UVV250-EN-XX180 - 870 nmN/A0.70N/AN/AN/AN/A400250 nm—
HR-6UVV250EN-XX180 - 870 nm0.53N/AN/AN/AN/AN/A400250 nm—
HR-6UVV300EN-XX200 - 650 nmN/AN/A0.58N/AN/AN/A600300 nm—
HR-6UVV330EN-XX250 - 790 nmN/A0.58N/AN/AN/AN/A500330 nm—
HR-6XR200EN-XX200 - 1000 nmN/A0.94N/A1.97N/AN/A300200 nm—
HR-6XR500EN-XX190 - 1100 nm0.71N/AN/AN/AN/AN/A300500 nm—
Extended-range options:HR-6XR200-XX220 - 1000 nm0.710.941.181.973.767.24300200 nm—
HR-6XR300-XX200 - 1100 nm0.710.941.181.983.767.24300Composite—
HR-6XR500-XX190 - 1100 nm0.710.941.181.973.767.24300500 nm—
Slit Options 5, 10, 25, 50, 100, 200 µm
Integration time 7.2 ms - 5 s
SNR (single scan @ 10 ms) 400:1
SNR (max. per second w/High Speed Averaging Mode) 3,500:1
Connectors SMA, TFM-108-02-L-DH Samtec, USB Type-C
Physical dimensions 148.8 x 106.4 x 48.2 mm
Weight 0.9306 kg
Temperature (operation) 0 °C - 55 °C
Temperature (storage) -30 °C - 70 °C